How to identify ssd devices on Solaris (MX000 Servers only)

1. Open one SSH on XSCF

Last login: Tue Mar 23 12:22:37 2010 from XXX.YYY.ZZZ.KKKK
XSCF>

2. Open on SSH session on your Solaris Server

Last login: Tue Mar 23 11:35:06 2010 from XXX.YYY.ZZZ.KKKK
Sun Microsystems Inc. SunOS 5.10 Generic January 2005
You have new mail.
[root@MYSERVER ]#

3. Verify your top disks I/O with iostat

Sample:
[root@MYSERVER ]# iostat -xM | grep ssd
ssd0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0 0
ssd43 0.0 0.0 0.0 0.0 0.0 0.0 0.9 0 0
ssd50 0.0 0.0 0.0 0.0 0.0 0.0 0.2 0 0
ssd61 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0 0
ssd62 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0 0
ssd148 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0 0
ssd159 0.3 0.6 0.0 0.0 0.0 0.0 2.0 0 0
ssd160 0.1 0.3 0.0 0.0 0.0 0.0 2.4 0 0
ssd201 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0 0
ssd202 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0 0
ssd203 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0 0
ssd296 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0 0
ssd333 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0 0

4. Verify the SSD Devices on XSCF of respective domain of server.

Sample:

# showdevices -a -v 01
01 01-2 ssd201 /dev/dsk/c4t500009740809C55Cd42s2Device being used by VxVM
01 01-2 ssd202 /dev/dsk/c4t500009740809C55Cd41s2Device being used by VxVM

Veritas Volume Manager (VxVM) – DG (Disk Group) Rename

1. Umount all filesystems used

# umount /myfilesystem1
# umount /myfilesystem2

2. Stop all volumes of Disk Group (DG)

# vxdg -g DG_APPS stopall

3. Deport the Disk Group (DG)

# vxdg deport DG_APPS

4. Import Disk Group with new name

# vxdg -n DG_DB import DG_APPs

SUN T2000 firmware update

Pré-requesite: You need a SUN Solaris installed on the hardware.

1. Go to sunsolve.sun.com and make login

2. Access: SunSystem Handbook > Select Category: Servers > (Servers) Select a Product: Sun Fire T2000

Direct link: http://sunsolve.sun.com/handbook_private/validateUser.do?target=Systems/SunFireT2000/SunFireT2000

3. Download the latest Flash PROM Patch (Version used on this note at 11/03/2010: 6.7.8)

4. Create dir /tmp/images

mkdir -p /tmp/images

5. Save the file 139434-05.zip on /tmp/images

6. Unzip the 139434-05.zip file

# unzip 139434-05.zip
Archive:  139434-05.zip
creating: 139434-05/
inflating: 139434-05/sysfw670_README_docs.css
inflating: 139434-05/Sun_System_Firmware-6_7_6-SPARC_Enterprise_T2000.bin
inflating: 139434-05/Sun_System_Firmware-6_7_6-Sun_Fire_T2000.bin
inflating: 139434-05/sysfwdownload.README
inflating: 139434-05/Sun_System_Firmware-6_7-download_SLA_and_Entitlement.txt
inflating: 139434-05/sysfw670_README_docs.html
inflating: 139434-05/sysfwdownload
inflating: 139434-05/Install.info
inflating: 139434-05/README.139434-05
inflating: 139434-05/copyright
inflating: 139434-05/LEGAL_LICENSE.TXT

6. Use the sysfwdownload to download the firmware to the System Controller

# ./sysfwdownload Sun_System_Firmware-6_7_6-Sun_Fire_T2000.bin
.......... (9%).......... (18%).......... (27%).......... (37%).......... (46%).......... (55%).......... (64%).......... (74%).......... (83%).......... (92%)......... (100%)

Download completed successfully.

7. Shutdown the Solaris OS

# shutdown -i0

8. Go to sc (use the #.)

9. Verify the actual version

sc> showhost
Sun-Fire-T2000 System Firmware 6.6.4  2008/07/01 01:59
Host flash versions:
OBP 4.28.9 2008/06/30 21:26
Hypervisor 1.6.4 2008/06/06 04:57
POST 4.28.6 2008/05/23 12:30
sc> showsc -v version
Advanced Lights Out Manager CMT v1.6.4
SC Firmware version: CMT 1.6.4
SC Bootmon version: CMT 1.6.4
VBSC 1.6.4.a
VBSC firmware built Jun  6 2008, 05:01:03
SC Bootmon Build Release: 01
SC bootmon checksum: 4D3BA6C7
SC Bootmon built Jun  6 2008, 05:11:28
SC Build Release: 01
SC firmware checksum: 91C164C1
SC firmware built Jun  6 2008, 16:52:21
SC firmware flashupdate SAT AUG 30 01:53:14 2008
SC System Memory Size: 32 MB
SC NVRAM Version = 14
SC hardware type: 4
FPGA Version: 4.1.10.7

10. Make the flash update
sc> flashupdate -s 127.0.0.1
SC Alert: System poweron is disabled.
......................................................................................................................................................................................
Update complete. Reset device to use new software.

SC Alert: SC firmware was reloaded

11. Reboot the sc

sc> resetsc
Are you sure you want to reset the SC [y/n]?  s
Are you sure you want to reset the SC [y/n]?  y
User Requested SC Shutdown

12. Now, check the actual version

sc> showsc
Sun-Fire-T2000 System Firmware 6.7.6  2009/10/29 16:06
Host flash versions:
OBP 4.30.4 2009/08/19 07:24
Hypervisor 1.7.3.a 2009/10/29 15:50
POST 4.30.4 2009/08/19 07:47
sc> showsc -v version
Advanced Lights Out Manager CMT v1.7.6
SC Firmware version: CMT 1.7.6
SC Bootmon version: CMT 1.7.6
VBSC 1.7.3.a
VBSC firmware built Oct 29 2009, 15:55:58
SC Bootmon Build Release: 01
SC bootmon checksum: B262D0C1
SC Bootmon built Oct 29 2009, 16:05:00
SC Build Release: 01
SC firmware checksum: 8BCE9F20
SC firmware built Oct 29 2009, 16:05:12
SC firmware flashupdate FRI FEB 26 20:18:50 2010
SC System Memory Size: 32 MB
SC NVRAM Version = 14
SC hardware type: 4
FPGA Version: 4.1.10.7